Show simple item record

dc.contributor.authorEgatama, Henda Febrian
dc.contributor.authorTriwiyono, Andreas
dc.contributor.authorSulistyo, Djoko
dc.date.accessioned2020-08-10T07:34:08Z
dc.date.available2020-08-10T07:34:08Z
dc.date.issued2020
dc.identifier.citationAmerican Concrete Institute, 2012, ACI 440.3R-12: Guide Test Methods for Fiber-Reinforced Polymer (FRP) Composites for Reinforcing or Strengthening Concrete and Masonry Structure, Farmington Hills: ACI. Asplund, S. O, 1949, Strengthening Bridge Slabs with Grouted Reinforcement, American Concrete Institue, 397-406. Bilotta, A., Ceroni, F., Barros, J. A., Costa, I., Palmieru, A., Szabo, Z. K., . . . Pecce, M. (2015), Bond of NSM FRP-Strengthened Concrete: Round Robin Test Initiative, American Society of Civil Engineers. Budipriyanto, A., Han, A. L., & Hu, H.-T, 2018, Bond-shear Behavior of FRP Rods as a Function of Attachment Configuration, Journal of Advanced Civil and Environmental Engineering, 1(1), 9-17. Caro, M., Jemaa, Y., Dirar, S., & Quinn, A, 2017, Bond Performance of Deep Embedment FRP Bars Epoxy-Bonded into Concrete, Elsevier Science, 147 (2017) 448-457. Lee, H., Jung, W., & Chung, W, 2017, Bond Behavior of Near Surface Mounted CFRP Rods Under Temperature Cycling, Elsevier, 67-75. Lorenzis, L. D., Rizzo, A., & Tegola, A. L, 2002, A Modified Pull-out Test for Near-Surface Mounted FRP Rods in Concrete, Elsevier Science, 33(Composites), 589-603. Mulyani, S, 2004, Tinjauan Kuat Lekat antara Baja Tulangan Tunggal dengan Bahan Perekat (Epoxy) pada Kedalaman Takikan 10 mm untuk Perkuatan Lentur Balok, Skripsi, Fakultas Teknik, Universitas Gadjah Mada, Yogyakarta. Seo, S.-Y., Feo, L., & Hui, D, 2012, Bond Strength of Near Surface-Mounted FRP Plate for Retrofit of Concrete Structures, Elsevier, 719-727. Soliman, S. M., El-Salakawy, E., & Benmokrane, B, 2011, Bond Performance of Near-Surface- Mounted FRP Bars, Journal of Composites for Construction ASCE, 15(1), 103-111. Wang, Q., Zhu, H., Li, T., Wu, G., & Hu, X, 2019, Bond Performance of NSM FRP Bars in Concrete with An Innovative Additional Ribs Anchorage System: An Experimental Study, Elsevier, 572-584. Wight, J. K., & MacGregor, J. G, 2012, Reinforced Concrete Mechanics and Design (6th ed.), New Jersey: Pearson Education. Zhang, S. S, 2018, Bond Strength Model for Near-Surface Mounted (NSM) FRP Bonded Joints: Effect of Concrete Edge Distance, Elsevier, 664-675.id_ID
dc.identifier.issn2580-8834
dc.identifier.urihttp://hdl.handle.net/11617/12124
dc.description.abstractPenelitian mengenai perkuatan eksternal (Near-surface Mounted) dengan menggunakan baja tulangan biasa perlu dilakukan, sebagai alternatif dari perkuatan FRP. Namun, sebelum penelitian tersebut dilakukan, penelitian pendahuluan diperlukan untuk mengetahui panjang penyaluran yang dibutuhkan, berdasarkan kekuatan lekat antara tulangan, bahan perekat (epoxy), dan beton. Metode pengujian yang dilakukan adalah dengan uji lolos tarik (pull out) tulangan ulir D13 yang direkatkan pada permukaan beton dengan kedalaman takikan 20 mm (1,5D) dengan epoxy adesif. Hasil dari penelitian ini menunjukkan bahwa tegangan lekat ultimit yang terjadi pada panjang terlekat 50 mm, 100 mm, 150 mm, dan 200 mm berturut-turut adalah 11,181 MPa, 19,972 MPa, 14,348 MPa, dan 10,235 MPa. Mode keruntuhan yang terjadi pada panjang terlekat 50 mm dan 100 mm adalah pecah pada beton (spalling), sedangkan pada 150 mm dan 200 mm adalah putus/luluh tulangan.id_ID
dc.language.isootherid_ID
dc.publisherSeminar Nasional Teknik Sipil X 2020id_ID
dc.titlePengaruh Panjang Terlekat terhadap Kekuatan Lekat Tulangan pada Beton sebagai Perkuatan Eksternal (Near-Surface Mounted)id_ID
dc.typeArticleid_ID


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record