    Study of Mechanical Properties of Prototype Optical Phase Conductor for Tropical Climate Conditions in Indonesia

    Thumbnail
    View/Open
    DAFTAR JUDUL PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT UNIVERSITAS MUHAMMADIYAH SURAKARTA TH 2013 LENGKAP.xlsx (20.74Kb)
    M19_TE5_Samsudi Rahardjo.pdf (270.0Kb)
    Date
    2013-12-05
    Author
    Rahardjo, Samsudi
    Solechan
    Metadata
    Show full item record
    Abstract
    Abstract Marginal areas especially rural communities still lack electrical lighting and telecommunications facilities. To access the electrical and telecommunications networks required huge costs because there is no infrastructure. To overcome this problem the government is targeting the national electrical capacity 57 thousand Megawatts in 2016 by appointing the State Electricity Company. Target national of Java-Bali distribution network throughout 27.779 km. PLN uses electricity transmission line from the plant to the substation through the tower-tower SUTT and SUTET. This study makes OPPC cable used for extra high voltage power conductors and internet network data that has reliable performance and durable. These goals will be achieved when the known characteristics and mechanical properties OPPC cable. Making cables OPPC by varying the amount of reinforcing steel galvanized wire and twisting torsional stress magnitude for analyzing mechanical properties ranging impact strength and tensile. The mechanical properties of artificial OPPC cable when compared with mechanical properties that are owned by the ACSR cable and commercial OPPC should be equal or close to its value before the applied field. The results of material testing OPPC cable diameter of 3 cm for Typevoltage torsional twisting 36/6/24 RBS 50% have the impact strength and tensile highest of 112.27 kN and 61.26 MPa. While the impact strength and tensile cables that OPPC least 3 cm in diameter with a voltage selection of the type of 36/6/24 RBS 25% of 63.24 kN and 36.36 MPa. The tensile strength and impact influenced the amount of galvanized steel wire and twisting torsional stress. The more galvanized steel wire and high torsional twisting voltage, proportional to the impact strength and tensile increased. When compared to ACSR cable and commercial OPPC, impact strength and tensile cables made OPPC nearing kekuatanya value, where the tensile strength and impact ACSR cable with voltage torsional twisting RBS 50% by 117 kNfrom 61.26 MPa, cables for commercial OPPC 116 kN from 63 MPa and un affected by ellectrical i
    URI
    http://hdl.handle.net/11617/4033
    Collections
    • Simposium Nasional Ke-12 RAPI 2013

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    Publikasi IlmiahCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV