Show simple item record

dc.contributor.authorSudarsana, I Ketut
dc.contributor.authorBudiwati, Ida Ayu Made
dc.contributor.authorAditya, Putu Wiyta
dc.date.accessioned2014-12-03T01:41:37Z
dc.date.available2014-12-03T01:41:37Z
dc.date.issued2014-12-04
dc.identifier.citation[1] SNI 2847:2013, Persyaratan Beton Struktural untuk Bangunan Gedung. Badan Standardisasi Nasional, Jakarta, 2013. [2] P. Pudjisuryadi and B. Lumantarna, “Evaluation of Columns Flexural Strength of Special Moment Resisting Frame in Accordance to the Indonesian Concrete and Earthquake Codes”, Proceeding International Conference on Earthquake Engineering and Disaster Mitigation (ICEEDM08), Jakarta, 2008. [3] J.M. Bracci and K.L. Dooley, “Seismic evaluation of column-to-beam strength ratio in reinforced concrete frames”, ACI Structural Journal, Vol. 98, No. 6, November-Desember 2001, pp 843-851 [4] K.J. Elwood and J.P. Moehle, “Seismic evaluation of column-to-beam strength ratio in reinforced concrete frames-Discussion”, ACI Structural Journal, September-October 2002, pp 710-711. [5] FEMA 356, Prestandard And Commentary For The Seismic Rehabilitation Of Buildings. Federal Emergency Management Agency, Washington D.C., 2000. [6] FEMA 273, NEHRP guidelines for the seismic rehabilitation of buildings, Federal Emergency Management Agency, Washington D.C. 1997. [7] SNI 1726:2012, Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung, Badan Standardisasi Nasional, Jakarta, 2012. [8] FEMA 440, Improvement of Nonlinear Static Seismic Analysis Procedures, Federal Emergency Management Agency. Washington D.C 2005. ICETIAen_US
dc.identifier.issn2407-4330
dc.identifier.urihttp://hdl.handle.net/11617/4973
dc.description.sponsorshipA ductile reinforced concrete structure shall be designed to ensure that plastic hinges occur as many as possible before collapse. This paper investigates the effect of column to beam strength ratio on performance of ductile reinforced concrete buildings. Fourteen interior frame models of two building categories which are five and ten stories buildings were modeled and analyzed. The main parameter among those models is column to beam strength ratio of 1.0 to 2.0 which are 1.0, 1.2, 1.4, 1.6, 1.8, and 2.0. The values are the ratio between column nominal strength (ΣMnc) and beam nominal strength (ΣMnb). In this study, the ratio between column strength to beam probable strength (ΣMprb) of 1.2 is also investigated. A static nonlinear pushover analysis was used to evaluate the performances of all models. Analysis results show that all models have a life safety performance level. A collapse mechanism of beam sway mechanism was achieved for strength ratios of 1.4 to 2.0 for five story frame models and 1.6 to 2.0 for ten story frames. The increase in the strength ratio up to 1.4 can increase ductility factor significantly, however, beyond that the strength ratio does not affect the ductility both for five and ten story frame models. Considering the ratio between column strength to beam probable strength of 1.2, the ductility factor increases by 16% and 25% respectively for five and ten stories, however, both frames still have performance level of life safety and collapse mechanism of column sway mechanism.en_US
dc.publisherUniversitas Muhammadiyah Surakartaen_US
dc.subjectPerformance levelen_US
dc.subjectcolum-to-beam strength ratioen_US
dc.subjectreinforced concreteen_US
dc.subjectductilityen_US
dc.titleEffect of Column to Beam Strength Ratio on Performance of Reinforced Concrete Framesen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record