Show simple item record

dc.contributor.authorZacoeb, Achfas
dc.date.accessioned2012-03-03T02:34:16Z
dc.date.available2012-03-03T02:34:16Z
dc.date.issued2006-01
dc.identifier.urihttp://hdl.handle.net/11617/69
dc.description.abstractFive reinforced concrete short rectangular columns with hollow made from PVC pipe that placed in the center of cross section were tested under eccentrically axial loading in compression region with load eccentricity of 60mm (e < eb). The hollow ratio was taken from 3.63% up to 20.28%, and concrete strength used was 34.52MPa. The columns had four longitudinal steel reinforcements of 12mm diameter were symmetrically placed in both sides of the square column section with average yield strength of 323.06MPa, and average modulus of elasticity of 257411.49MPa. The objective of this research is to study the ductility of hollow RC short columns with square cross section of 150mm x 150mm. The results show that generally all columns give significant difference in ductility escalation. The maximum ductility escalation was occurred at column with maximum hollow ratio (20.28%), that is 16.38%, compared relatively to the solid column. It could be stated that PVC pipe installation in column will improve the ductility.en_US
dc.subjectductilityen_US
dc.subjecthollow ratioen_US
dc.subjectRC short columnen_US
dc.subjectsquare cross sectionen_US
dc.subjectcompression regionen_US
dc.titleDUCTILITY OF HOLLOW RC SHORT COLUMNS IN COMPRESSION REGIONen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record