Show full item recordAbstract
Tower is one of the facility to support signal which is influenced by the elevation factor. For a tower at high
elevation, the influence of wind will be very significant to the structure. Therefore, wind site survey should be conducted
prior to tower design. The type of tower considered is tapered monopole of 120 m high constructed at Meteorology and
Geophysics Station, Semarang. The measurement of anemometer and data analysis resulting in wind velocity of 10-year
return period. It was obtained that the maximum wind velocity was 100.8 km/hour or equivalent to 28 m/sec and this will
the input for the following analysis. The upper structure analysis is carried out with the help of MsTower which is
referred to EIA/TIA-F and LRFD concept.
With input of maximum velocity obtained from survey, the tower was analyzed for internal forces. The axial forces is
115.0466 ton and moment about x-axis of 16.00 ton-m.